Mean Well CLG-60-27LED Power Supply
The CLG-60 family features: * Universal AC Input * Short Circuit / Overload / Over Voltage / Over Temperature Protection Circuits * Built-in active PFC function * IP67 design for indoor or outdoor installations * UL1310,Class 2 safety approval * Cooling by free air convection * 100% full load burn-in test * Suitable for LED lighting and moving sign applications * High Reliability with > 495k Hours MTBF * 3 Year Warranty * Constant Current / Constant Voltage Mode Power Supply |
| ||||||||||||
| Need Assistance? Give us a call at (866) 588-1750 | |||||||||||||
Mean Well CLG-60 Electrical Specifications | |
| OUTPUT RATING | 27V @ 2.3A / 18.9-27 @ A |
| Input Voltage | Universal AC input Range (90-295VAC) |
| Input Frequency | 47-63 Hz |
| Inrush | 40A max @ 230VAC (cold start) |
| Input Current | 800mA max @ 115VAC / 400mA max @ 230VAC (continuous) |
| Leakage | <500uA maximum @ 240 VAC |
| Hold-Up | 30ms at 115VAC / 60ms @ 230VAC (full load) |
| Efficiency | 83-88% Typical (depending on output model) |
| Harmonics | EN61000-3-2, 3 Class C Compliant |
| V Adjustment Range | Fixed - Factory Set Point of -5 / +10% rated voltage |
| current adjust | Fixed - Factory can set 75-103% of rated current |
| Regulation | +/-4% Line / +/-10% Load |
| Ripple | 2-4.6V pk-pk maximum (20MHz) |
| Setpoint Accuracy | +/-10 % (maximum) |
| Over Current | Constant current limiting, auto-recovery (output table for trip points) |
| Over Voltage Protection | 115-135% (latching) |
| Operating Temperature | -30 to +70C (refer to derating curve) |
| Storage Temperature | -40C to +80C max. |
| Cooling | Convection Cooled Operation |
| Humidity | 20-90%RH (non-condensing) |
| Vibration | 10-500Hz, 5G 10min/1 cycle for 60 min (3 axes) |
| Shock | 20G Peak Acceleration |
| Reliability | >495K hours minimum per MIL-HDBK-217F (25C) |
| Weight (lbs) | 1.9 |
Credit / Terms
|